BASIC WIRING EXAMPLES
EGND AC IN WOA WO W1 PWR GND
RED
LED
WIEGAND INPUT
GRN
LED
SNDR
DRIVE
(+) (–)
TX
(YEL)
RX
(GRN)
N/O N/C COM
AUX RELAY KYPD PWR
LOCK
PWR
(+)
COM N/C N/O
MAIN RELAY
LOCK
PWR
(–)
DOOR
POSITION
CONTACT
REMOTE
RELEASE
INPUT
T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 T15 T16 T17 T18 T19 T20 T21 T22 T23 T24 T25 T26 T27
N/O
Momentary
Switch
NETPDK
HID
HID CORPORA TION
MAG LOCK
(OR
FAIL-SAFE
ELECTRIC
DOOR
STRIKE)
N/C
Emergency Exit
Switch (or Fire
Panel Relay)
Jumper
Wire
One Door / One Keypad / Magnetic Lock or Electric Door Strike
As shown below, the Magnetic Lock and Fail-Safe Electric Door Strike wiring are identical. Do NOT use Fail-Secure devices for fire exit
doors! In the event of power loss, Fail-Secure devices remain "secure" (locked).
The keypad interrupts MAG LOCK (or Fail-Safe Electric Door Strike) power upon a successful User Code entry (or Prox Card presenta-
tion), initiating "Pass Time" (time the door remains unlocked). The default Pass Time is 3 seconds, but you can change this time to 10 or
15 seconds using Functions 52-54 (see the keypad programming instructions WI1855).
TSD = Transient Suppression Device (two supplied): Mount the TSD as close to the device to be protected as possible.
Door
Position
Contact
ELECTRIC DOOR
STRIKE
(FAIL-SECURE)
NOT FOR FIRE EXITS
EGND AC IN WOA WO W1 PWR GND
RED
LED
WIEGAND INPUT
GRN
LED
SNDR
DRIVE
(+) (–)
TX
(YEL)
RX
(GRN)
N/O N/C COM
AUX RELAY KYPD PWR
LOCK
PWR
(+)
COM N/C N/O
MAIN RELAY
LOCK
PWR
(–)
DOOR
POSITION
CONTACT
REMOTE
RELEASE
INPUT
T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 T15 T16 T17 T18 T19 T20 T21 T22 T23 T24 T25 T26 T27
N/O
Momentary
Switch
SECONDARY
NETPDK
MAG LOCK
(OR
FAIL-SAFE
ELECTRIC
DOOR
STRIKE)
N/C
Emergency Exit
Switch (or Fire
Panel Relay)
Jumper
Wire
One or Two Doors / Two Keypads or Two Wiegand Devices
Magnetic Lock and/or Electric Door Strike
The system is capable of controlling two doors using up to two of any combination of NETDK or NETPDK keypads, PLUS up to two Wie-
gand devices. Two auxiliary Form-C relays are available for up to two of any combination of magnetic locks and/or electric door strikes.
Door
Position
Contact
ELECTRIC DOOR
STRIKE
(FAIL-SECURE)
NOT FOR FIRE EXITS
PRIMARY
NETDK
Red (+ DC)
White (Data 1)
Green (Data 0)
Black (- Ground)
Green (Data 0)
Brown (Red LED)
Orange (Green LED)
Yellow (Beeper)
PRIMARY
WIEGAND**
SECONDARY
WIEGAND**
Red
Black
Yellow
Green
*TSD = Transient Suppression Device (two supplied): Mount the TSD as close to the device to be protected as possible.
**Example device shown: HID ProxPoint
®
Plus Model 6005B.
Red
Black
Yellow
Green
TSD*
TSD*
TSD*
TSD*