24
60. Number of Attempts Before Lockout
61. Set the Attempts Lockout Time
• Number of attempts before lockout must be 1-9 attempts.
• The number of attempts is reduced by half every time the keypad is locked out without a
successful code entry (default is 6 attempts).
• The attempt count is reset each time a valid code is entered.
• Lockout Time must be 1-60 seconds.
How long the keypad is locked-out after a series of unsuccessful attempts
(default is 18 seconds).
4
4
LOCKOUT
; 6 4 :
64. Disable Remote Input
• Wire a Normally Open Contact to Wires (White & White). Momentarily close switch to unlock door
to allow person to pass through door.
• Enter the functions below to Disable/Enable the Remote Input.
NOTE: The Remote Input is enabled as part of the default program.
Remote Input
; 6 5 :
65. Enable Remote Input
; 6 6 ; [ _ _ ] :
(Ambush Code)
66. Ambush Code
• Ambush code must be 2 digits.
• An error will sound if the Ambush Code matches the 1st two digits of any User Code.
See Function 67 for more information about the Ambush Function.
2
3
REMOTE INPUT
AMBUSH
; 6 0 ; [ _ ] :
(Number of Attempts)
; 6 1 ; [ _ _ ] :
(Lockout Time)
62-63. Reserved
Programming Functions (cont'd)
59. Reserved