NX-4 Control
Page 24
LOCATION 81 - ASTART PROGRAM AND END PROGRAM@ CODES (4 segments, numerical data)
Location 81 contains the tens and ones digits for a 4+2 format that will be sent if "Start / End Programming
Reporting" is enabled. Segment 1 contains the tens digit of the "Start Program Reporting". Segment 2 contains the
ones digit of the "Start Program Reporting". Segment 3 contains the tens digit of the "End Program Reporting".
Segment 4 contains the ones digit of the "End Program Reporting".
LOCATION 82 - AEND DOWNLOAD@ CODE (4 segments, numerical data)
Location 82 contains the tens and ones digits for a 4+2 format that will be sent if "End Downloading Reporting" is
enabled. Segment 1 and 2 are reserved. Segment 3 contains the tens digit of the "End Download Reporting".
Segment 4 contains the ones digit of the "End Download Reporting". Note: A start download report will be sent to the
internal event log.
LOCATION 83 - ACANCEL@ CODE (1 segment, numerical data)
Location 83 contains the tens digit for a 4+2 format that will be sent if "Cancel Reporting" is enabled. Segment 1
contains the tens digit for the "Cancel Communicator Reporting". The ones digit is the ones digit of the user who
canceled. If it is required to report Cancels for more than 9 users, Contact ID or SIA format must be used.
CUSTOMIZING ZONE TYPES (Configuration Groups)
NOTE: Locations 110-149 are used to change the zone types (configurations) as listed in the table on
page 25. These locations are considered advanced programming and should only be changed with a
thorough understanding of the operation of each bit.
Table 1.1
GROUP CHARACTERISTIC SELECTIONS
Segment 1
1 = Fire (turn on if this is a fire zone).
2 = 24 hour (turn on for non-fire 24 hour zones).
3 = Reserved
4 = Follower (turn on for burglary zones that are Instant during non-entry times).
5 = Delay 1 zone (follows timer 1 entry and exit times).
6 = Delay 2 zone (follows timer 2 entry and exit times).
7 = Interior (turn on if zone should Automatically Bypass or Bypass for Stay Arming).
8 = Local only (turn on if this zone should not be reported).
Segment 2
1 = On will beep the keypad for alarm.
2 = On will sound the yelping siren for alarm.
3 = On will sound the temporal siren for alarm.
4 = On will chime.
5 = On will bypass.
6 = On will include in the group shunt.
7 = On is force armable.
8 = On is entry guard.
Segment 3
1 = RESERVED
2 = On enables Double End Of Line Tamper zone. (Mainly used for tamper on wireless zones)
3 = On enables Trouble Reporting zone. (Day zone and Fire zones)
4 = On enables Cross Zoning.
5 = On enables Dialer Delay zone. (See location 40, page 18)
6 = On enables swinger shutdown. (See location 38, page 18)
7 = On enables Restore reporting.
8 = On enables Listen-In. (See location 40, page 18)
LOCATION 110 - GROUP 1 ALARM EVENT CODE (1 segment, numerical data)
Location 110 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 34. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2 the digit in location 110 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 111 - GROUP 1 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use Table 1.1 AGroup Characteristic Selection@ above to program this location.