USERS (Continued)
; 6 :
6. Enable Total User Lockout Mode
(This Function enabled through keypad only)
7. Disable Total User Lockout Mode
(This Function enabled through keypad only)
; 7 :
User Lockout Mode
Disables all User Codes (Except the User Number 1 Master Code). Note: No other programming functions or schedules
(including a DL-Windows data transfer) will re-enable User Codes. User Codes must
be re-enabled with Function 7. Note: Does
not change the User enable/disable status. Note: If the NETWORXPANEL is currently in Passage Mode ("door unlocked") and
Function 6 is programmed, the NETWORXPANEL will remain in Passage Mode.
M
5. User Enable with Timeout
(Enter Timeout, XXX Hours)
(This Function enabled through keypad only)
; 5 ; [ _ _ _ _ ] ; [ _ _ _ _ ] :
(User Number) (XXX Hours)
With Function 5, User Numbers must be between 2-5000, hours must be between 001-999.
Function 5 can temporarily override a disabled User (disabled using Function 3 above).
Since this is a temporary feature, Function 5 can only be enabled using the keypad.
Example: Brian, User Number 1157, rarely works at the office, but when he does, enable him for his 8 hour work day by en-
tering Program Mode and pressing: ; 5 ; 1157 ; 008 :.
NOTE: Up to 4 Timeout Functions may be pending at any one time. An error beep will sound when attempting to program more
than 4 Timeout Functions.
2
Service Code is a One-Time-Only Code. Once it is used, it is disabled until enabled again.
NOTE: User Number 297 is used to reset Service Code Use. See "Terminology Used in this Manual" on page 7 for more
information and examples regarding special Users 297-300.
; 9 :
9. Enable User 300 (Service Code)
2
; 1 0 ; 0 0 0 :
10. Erase All Users Except the Master Code (User 1)
(This Function enabled through keypad only)
Erases all User Codes except the Master Code (User 1).
Function 10 can only be performed using the keypad.
M
11. Reserved
3. Disable User
; 3 ; [ _ _ _ _ ] :
(User Number)
4. Enable User
; 4 ; [ _ _ _ _ ] :
(User Number)
User Enable/Disable (By User Number)
User Number must be between 2 and 5000.
NOTE: Use Feature 3 to disable a specific User Number and their associated User Code. Will Enable/Disable Users even if the
User is associated with an enabled Group. If the disabled User Code is entered, the NETPDK will flash 1 green and 4 red flashes
(with 1 long and 5 short beeps) indicating that the User Code exists in memory, but is disabled. Function 4 will "undo" Function 3.
2
Programming Functions (cont'd)
Allows Program Mode exit for keypads without hold-down functionality, such as some Wiegand readers with integral keypads.
; 8 :
8. Exit Program Mode
3