15
USERS (Continued)
; 6 :
6. Enable Total User Lockout Mode
(This Function enabled through keypad only)
7. Disable Total User Lockout Mode
(This Function enabled through keypad only)
; 7 :
User Lockout Mode
Disables all User Codes (Except the User Number 1 Master Code). Note: No other programming functions or schedules
(including a DL-Windows data transfer) will re-enable User Codes. User Codes must
be re-enabled with Function 7. Note: Does
not change the User enable/disable status. Note: If the NETWORXPANEL is currently in Passage Mode ("door unlocked") and
Function 6 is programmed, the NETWORXPANEL will remain in Passage Mode.
M
5. User Enable with Timeout
(Enter Timeout, XXX Hours)
(This Function enabled through keypad only)
; 5 ; [ _ _ _ _ ] ; [ _ _ _ _ ] :
(User Number) (XXX Hours)
• With Function 5, User Numbers must be between 2-5000, hours must be between 001-999.
• Function 5 can temporarily override a disabled User (disabled using Function 3 above).
• Since this is a temporary feature, Function 5 can only be enabled using the keypad.
• Example: Brian, User Number 1157, rarely works at the office, but when he does, enable him for his 8 hour work day by en-
tering Program Mode and pressing: ; 5 ; 1157 ; 008 :.
NOTE: Up to 4 Timeout Functions may be pending at any one time. An error beep will sound when attempting to program more
than 4 Timeout Functions.
2
Service Code is a One-Time-Only Code. Once it is used, it is disabled until enabled again.
NOTE: User Number 297 is used to reset Service Code Use. See "Terminology Used in this Manual" on page 7 for more
information and examples regarding special Users 297-300.
; 9 :
9. Enable User 300 (Service Code)
2
; 1 0 ; 0 0 0 :
10. Erase All Users Except the Master Code (User 1)
(This Function enabled through keypad only)
Erases all User Codes except the Master Code (User 1).
• Function 10 can only be performed using the keypad.
M
11. Reserved
3. Disable User
; 3 ; [ _ _ _ _ ] :
(User Number)
4. Enable User
; 4 ; [ _ _ _ _ ] :
(User Number)
User Enable/Disable (By User Number)
• User Number must be between 2 and 5000.
NOTE: Use Feature 3 to disable a specific User Number and their associated User Code. Will Enable/Disable Users even if the
User is associated with an enabled Group. If the disabled User Code is entered, the NETPDK will flash 1 green and 4 red flashes
(with 1 long and 5 short beeps) indicating that the User Code exists in memory, but is disabled. Function 4 will "undo" Function 3.
2
Programming Functions (cont'd)
Allows Program Mode exit for keypads without hold-down functionality, such as some Wiegand readers with integral keypads.
; 8 :
8. Exit Program Mode
3